ELS-1
Enclosure Leakage Sensor
Indication via LED and Advanced Diagnostics, Intrinsically safe, FISCO or Entity, For instrument or device coupler, Fits inside terminal compartment, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.23.500
Fieldbus Power Hub, Compact Power Supply Module
Output: 21 … 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.500
Fieldbus Power Hub, Compact Power Supply Module
Output: 28 … 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-DM-A
Fieldbus Power Hub, Advanced Diagnostic Module
Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-GTR-4PA
PROFIBUS Power Hub, Gateway Module
PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting
KT-MB-GT2AD.FF
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA
KT-MB-GT2AD.FF.IO
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA
R-SP-E12
Fieldbus Segment Protector
12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zone 1/Div. 2, Instruments in Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
FDH-1
Fieldbus Diagnostic Handheld
Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-DM-B
Fieldbus Power Hub, Basic Diagnostic Module
Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play – no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KFD2-BR-1.PA.1500
Basic Segment Coupler
Output: 24 … 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting
KLD0-SAA
Voltage adjustment module
Series voltage reducing module, Removable terminals, Polarity reversal protected, Installation in cabinet on DIN mounting rail, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KLD2-FBPS-1.25.360
Fieldbus Power Supply
Output: 25 … 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
BP-FBPS-1.30.1
Portable Fieldbus Battery
Adjustable output 15 … 30 V/max.1 A , 8 hours operation at 500 mA without recharging, IP 54 – Rain and splash proof, Rugged housing for outdoor use, For FOUNDATION Fieldbus H1 and PROFIBUS PA
Digi OneĀ® IA
COM Port Converter
Selectable serial interface RS 232, RS 422 or RS 485, Switchable RS-485 terminator, DIN rail mounting, 9…30 V DC input, 10/100 Base-T Ethernet support
EI-0D2-10Y-10B
Intrinsically safe Ethernet Isolator
Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
FBTA-228-BPFB-R-8R
Compact Fieldbus Power Hub, Motherboard for Invensys FBM 228
8 segments, redundant, individual modules per segment, Customized for Invensys, FBM228, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
HD2-DM-A.RO
Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play – no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-GTR-4PA.PN
PROFINET Power Hub, Gateway Module
Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics
KFD2-BR-Ex1.3PA.93
Segment Coupler 1
Output: 12.6 … 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator
KLD2-FBPS-1.12.220
Fieldbus Power Supply
Output: 12 … 13 V/220 mA, For battery or solar-powered applications, For demanding environmental conditions , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
KLD2-PR-1.IEC
Fieldbus Power Repeater
Output: 24 … 26 V/400 mA, For extension of fieldbus segments, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KT-MB-DMA
Advanced Diagnostic Module, Kit for stand-alone Operation
Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KT-SRT-FF
Starter Kit for FOUNDATION Fieldbus H1 Infrastructure
Complete hardware for connection of FOUNDATION Fieldbus H1 field devices to the host system of your choice, Output: 25 … 28 V/360 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
KT-SRT-PA
Starter Kit for PROFIBUS PA Infrastructure
Complete hardware for connection of PROFIBUS PA field devices to a DP-Master, Output: 24 … 26 V/400 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
USB-FBPS-1.11.45.NI
USB Fieldbus Power Supply
Output: min. 11 V/45 mA, For 1…2 devices/test setups, In conjunction with NI PCMCIA-FBUS card, Permitted for Zone 2 operation, For FOUNDATION Fieldbus H1
HD2-FBPS-1.500
Fieldbus Power Hub, Power Supply Module
Output: 28 … 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
EI-0D2-10Y-10B-Y1
Intrinsically safe Ethernet Isolator
Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
HD2-FBPS-1.17.500
Fieldbus Power Hub, Power Supply Module
Output: 15 … 17 V/500 mA, Voltage limitation for FISCO ic, Entity ic, also FNICO and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-FBPS-1.23.500
Fieldbus Power Hub, Power Supply Module
Output: 21 … 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-FBPS-1.25.360
Fieldbus Power Hub, Power Supply Module
Output: 25 … 28 V/360 mA, Universal power supply for most applications, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
MB-FB-4R.HO.SC
High-Density Fieldbus Power Hub, Motherboard for Honeywell C-Series
4 segments, redundant, individual modules per segment, Customized for Honeywell, C-Series, High-power trunk: Live work on devices in any hazardous area, Optimized for size and quality, low heat dissipation, For FOUNDATION Fieldbus H1
FBTA-228-BPFB-8
Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228
8 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best signal quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
FBTA-228-BPFB-R-4R
Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228
4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best signal quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KLD2-PR-Ex1.IEC1
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus signal, Extension of the transmission distance by means of opening a new fieldbus segment
KLD2-PR-Ex1.IEC
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to Entity, 70 mA supply of the field side, Improves the fieldbus signal, Extension of the transmission distance by means of opening a new fieldbus segment
DM-AM-KIT
Mobile Advanced Diagnostic Module
Comprehensive diagnostics for the fieldbus physical layer, Mobile kit for the fieldbus professional, Precise measurements through passive circuits, For commissioning and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
DP-LBF-I1.36.*
Fieldbus Surge Protector, Cabinet Installation, Ex ia
Modular: protection module easy to replace, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Protection module replaceable, interrupting or non-interrupting, Grounding of shield direct or via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-FT-Ex1
Fieldbus Terminator, Field Installation, Ex ia
Terminator in stainless steel housing, Intrinsically safe, FISCO and flameproof enclosure (Ex d), Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-FT-Ex1.D.IEC
Fieldbus Terminator, Field Installation, Ex d
Terminator in stainless steel housing, Flameproof enclosure (Ex d) protection, Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-FT-Ex1.I.IEC
Fieldbus Terminator, Field Installation, Ex ia
Terminator in stainless steel housing, Intrinsically safe, FISCO, Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-LBF-D1.32
Fieldbus Surge Protector, Field Installation, Ex d
Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge protection for ‘+’ and ‘-‘ fieldbus lead, Choice of threads 20 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-LBF-I1.32
Fieldbus Surge Protector, Field Installation, Ex ia
Surge Protector in stainless steel housing, Intrinsically safe, FISCO or Entity, Surge protection for ‘+’ and ‘-‘ fieldbus lead, Choice of threads 20 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB0.P**.A**.1.0.***.***.****
FieldBarrier Junction Box, Polyester (GRP)
4, 8 or 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB0.S**.A**.1.0.***.***.****
FieldBarrier Junction Box, Stainless Steel
4, 8 or 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB1.P14.A**.1.*.***.***.****
FieldBarrier Junction Box, Polyester (GRP)
8, 10, 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB1.S14.A**.1.*.***.***.****
FieldBarrier Junction Box, Stainless Steel
8, 10, 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SP5.P**.B**.1.0.***.***.***0
Segment Protector Junction Box, Polyester (GRP)
4 … 12 outputs Ex ic (FISCO or Entity), Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SP5.S**.B**.1.0.***.***.***0
Segment Protector Junction Box, Stainless Steel
4 … 12 outputs Ex ic (FISCO or Entity), Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SPE.P**.A**.1.0.***.***.****
Segment Protector Junction Box, Polyester (GRP)
Connection of Ex d certified devices, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SPE.S**.A**.1.0.***.***.****
Segment Protector Junction Box, Stainless Steel
Connection of Ex d certified devices, Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.TI0.P12.*08.F.0.***.***.**00
Temperature Multi-Input Junction Box, Polyester (GRP)
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.TI0.P12.*08.P.0.***.***.**00
Temperature Multi-Input Junction Box, Polyester (GRP)
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.TI0.S12.*08.F.0.***.***.**00
Temperature Multi-Input Junction Box, Stainless Steel
8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.TI0.S12.*08.P.0.***.***.**00
Temperature Multi-Input Junction Box, Stainless Steel
8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.VC0.P21.A04.*.*.***.***.*000
Valve Coupler Junction Box, Polyester (GRP)
4 valve control and 8 position feedback signals, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.VC0.S20.A04.*.*.***.***.*000
Valve Coupler Junction Box, Stainless Steel
4 valve control and 8 position feedback signals, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2-JB-#.*
Fieldbus junction box
4 … 8 outputs Ex ia, ib, Installation in non-explosion hazardous area, Instruments in non-explosion hazardous area, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Supports FISCO and Entity
F2-JB-I#.*
Fieldbus junction box
4 … 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0…1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2-SP-IC*
Fieldbus Segment Protector
4 … 10 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2D0-FB-Ex4.*
FieldBarrier
4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0…1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2D0-MIO-Ex12.FF.*
Multi-Input/Output Device with Aluminum Housing
For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F2D0-MIO-Ex12.PA.*
Multi-Input/Output Device with Aluminum Housing
For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F2D0-TI-Ex8.FF.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
F2D0-TI-Ex8.PA.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
FD0-BI-EX12.PA
Sensor Interface
For 12 intrinsically safe binary inputs, Installation in Zone 1 and Zone 2, Sensors in Zone 0, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
FD0-VC-EX4.FF
Valve Coupler
For four intrinsically safe valves with position sensors, Installation in Zone 1 and Zone 2, Valves in Zone 0, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
FD0-VC-EX4.PA
Valve Coupler
For four intrinsically safe valves with position sensors, Installation in Zone 1 and Zone 2, Valves in Zone 0, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
MB-FB-GTR1
Fieldbus Power Hub, Gateway Motherboard
For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable
MBHC-FB-4*
Compact Fieldbus Power Hub, Motherboard, Common Interface
4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4.GT
Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules
4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics
MBHC-FB-4.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
MBHC-FB-4.YO*
Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111
4 segments, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4R*
Compact Fieldbus Power Hub, Motherboard, Common Interface
4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4R.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
MBHC-FB-4R.YO*
Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF 111
4 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R*
Compact Fieldbus Power Hub, Motherboard, Common Interface
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R.RH*
Compact Fieldbus Power Hub, Motherboard, Redundant Host Terminals
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, redundant terminals, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
MBHC-FB-8R.YO*
Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111
8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
R2-SP-IC*
Segment Protector for Cabinet Installation
4 … 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
R4D0-FB-IA*
FieldBarrier
8 … 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0…1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
R8D0-MIO-Ex12.FF*
Multi-Input/Output Device for Cabinet Installation
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
R8D0-MIO-Ex12.PA*
Multi-Input/Output Device for Cabinet Installation
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
RD0-FB-Ex4.*
FieldBarrier
4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0…1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
RD0-TI-Ex8.FF.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
RD0-TI-Ex8.PA.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
RM-SP*
Modular Segment Protector for Cabinet Installation
2 outputs Ex nL, expandable to up to 26 with short-circuit protection, High-power trunk for high device count and long cable lengths, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SCP-LBF-IA1.36.IE*
Fieldbus Surge Protector, Field Installation on Spur
Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-AL*.***
Segment Protector Junction Box, Aluminum
Intrinsically safe (Ex ic)/non-incendive outputs, Anodized aluminum, IP67, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-CS*.***
Segment Protector Junction Box, Carbon Steel
Intrinsically safe (Ex ic)/non-incendive outputs, Carbon steel, NEMA 4, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-FB*.***
Segment Protector Junction Box, Polyester (GRP)
Intrinsically safe (Ex ic)/non-incendive outputs, Glass fiber reinforced polyester, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-PCW.***
Segment Protector Junction Box, Polycarbonate
Intrinsically safe (Ex ic)/non-incendive outputs, Impact resistant polycarbonate, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-SS*.***
Segment Protector Junction Box, Stainless Steel
Intrinsically safe (Ex ic)/non-incendive outputs, Stainless steel, brushed NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
TCP-LBF-IA1.36.IE*
Fieldbus Surge Protector, Field Installation on Trunk
Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
TPH-LBF-IA1.36.DE*
Fieldbus Surge Protector, Trunk Installation on Power Hub
Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield direct, For FOUNDATION Fieldbus H1 and PROFIBUS PA