Analog Input
FB3205B2
HART Transmitter Power Supply, Input Isolator
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB3305B2
HART Transmitter Power Supply, Input Isolator
4-channel, Inputs with plug-in Ex e terminals, Power supply for 2-wire transmitters with 4 mA … 20 mA, Supply circuit 15 V (20 mA)
FB3201B2
Transmitter Power Supply, Input Isolator
1-channel, Fully compatible replacement for FB3201B, Input Ex ia, Installation in suitable enclosures in Zone 1
FB3202B1
HART Transmitter Power Supply, Input Isolator
1-channel, Input Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB3202B2
HART Transmitter Power Supply, Input Isolator
1-channel, Input Ex ia, Power supply for 2- or 3-wire transmitters with 4 mA … 20 mA, Module can be exchanged under voltage (hot swap)
FB3203B2
HART Transmitter Power Supply, Input Isolator
1-channel, Fully compatible replacement for FB3203B, Input Ex ia, Installation in suitable enclosures in Zone 1
FB3204B2
Transmitter Power Supply, Input Isolator
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB3302B2
HART Transmitter Power Supply, Input Isolator
1-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
Digital Input
FB1208B
Digital Input
8-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB1201B
Digital Input
2 channels, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB1202B
Digital Input
3-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB1308B2
Digital Input
8-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB1301B2
Digital Input
2-channel, Inputs with plug-in Ex e terminals, Module can be exchanged under voltage (hot swap), Installation in suitable enclosures in Zone 1
FB1302B2
Digital Input
3-channel, Fully compatible replacement for FB1302**, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1
Analog Output
FB4205B2
HART Output Isolator
4-channel, Outputs Ex ia, Module can be exchanged under voltage (hot swap), Installation in suitable enclosures in Zone 1
FB4205C2
HART Output Isolator with Shutdown Input
4-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB4201B2
Output Isolator
1-channel, Output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB4202B2
HART Output Isolator
1-channel, Output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB4204B2
Output Isolator
4-channel, Fully compatible replacement for FB4204B, Outputs Ex ia, Installation in suitable enclosures in Zone 1
FB4302B2
HART Output Isolator
1-channel, Outputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Analog output module for 0/4 mA … 20 mA
Digital Output
FB6208B
Digital Output with Shutdown Input
8-channel, Outputs Ex ib, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB6208C
Digital Output with Shutdown Input
8-channel, Outputs Ex ib, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB6308B2
Digital Output with Shutdown Input
8-channel, Outputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB6210B
Digital Output
4-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB2201E
Digital Output with Shutdown Input
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB2203B
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB2201B
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB2203E
Digital Output with Shutdown Input
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB2204B
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB2212B
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB2212E
Digital Output with Shutdown Input
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB2213B
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
FB2213E
Digital Output with Shutdown Input
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
Com Units
FB8205*
Com Unit for PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, HART communication via PROFIBUS DP V1 or service bus
FB8206*
EasyCom Com Unit for PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, HART communication via PROFIBUS DP V1 or service bus
FB8207*
Com Unit for MODBUS RTU
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS RTU, HART communication via service bus
FB8209*
Unicom Com Unit for PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, HART communication via PROFIBUS DP V1 or service bus
FB8210*
Com Unit for FOUNDATION Fieldbus Modular I/O
Interface between the I/O modules and the PCS/PLC, Com unit for 20 analog or 40 digital channels, Communication via FOUNDATION Fieldbus H1, HART communication via service bus
FB8211*
Com Unit for MODBUS TCP
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS TCP, HART communication via MODBUS TCP
Analog Input
LB3005A2
HART Transmitter Power Supply, Input Isolator
4-channel, Power supply for 2-wire transmitters with 4 mA … 20 mA, Installation in Zone 2 or safe area, Supply circuit 15 V (20 mA)
LB3105A2
HART Transmitter Power Supply, Input Isolator
4-channel, Inputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Power supply for 2-wire transmitters with 4 mA … 20 mA
LB3106A
HART Transmitter Power Supply
4-channel, Inputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Power supply for 2-wire transmitters with 4 mA … 20 mA
LB7104A
Universal Input/Output (HART)
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Analog input, digital input,
analog output, digital output
LB3002A2
HART Transmitter Power Supply, Input Isolator
1-channel, Power supply for 2- or 3-wire transmitters with 4 mA … 20 mA, Installation in Zone 2 or safe area, Supply circuit 15 V (20 mA)
LB3102A1
HART Transmitter Power Supply
1-channel, Input Ex ia, Installation in Zone 2, Div. 2 or safe area, Power supply for 2-wire transmitters with 4 mA … 20 mA
LB3102A2
HART Transmitter Power Supply, Input Isolator
1-channel, Input Ex ia, Installation in Zone 2, Div. 2 or safe area, Power supply for 2- or 3-wire transmitters with 4 mA … 20 mA
LB3104A2
Transmitter Power Supply, Input Isolator
4-channel, Inputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Power supply for 2-wire transmitters with 4 mA … 20 mA
LB7004A
Universal Input/Output (HART)
4-channel, Analog input, digital input,
analog output, digital output, Installation in Zone 2 or safe area, Supply circuit 21.5 V (4 mA)
LB3006A
HART Transmitter Power Supply
4-channel, Power supply for 2-wire transmitters with 4 mA … 20 mA, Installation in Zone 2 or safe area, Supply circuit 21.5 V (4 mA)
LB3101A2
Transmitter Power Supply, Input Isolator
1-channel, Input Ex ia, Installation in Zone 2, Div. 2 or safe area, Power supply for 2- or 3-wire transmitters with 4 mA … 20 mA
LB3103A2
HART Transmitter Power Supply, Input Isolator
1-channel, Input Ex ia, Installation in Zone 2, Div. 2 or safe area, Power supply for 2- or 3-wire transmitters with 4 mA … 20 mA
Digital Input
LB1009A
Digital Input
8-channel, Inputs Ex ic, Installation in Zone 2 or safe area, Dry contact or NAMUR inputs
LB1109A
Digital Input
8-channel, Inputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Dry contact or NAMUR inputs
LB1002A
Digital Input
3-channel, Dry contact or NAMUR inputs, Installation in Zone 2 or safe area, Positive or negative logic selectable
LB1102A
Digital Input
3-channel, Inputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Dry contact or NAMUR inputs
LB1014A
Digital Input
15-channel, Active digital signal 95 V AC … 230 V AC, Positive or negative logic selectable, Simulation mode for service operations (forcing)
LB1008A
Digital Input
8-channel, Dry contact or NAMUR inputs, Installation in Zone 2 or safe area, Positive or negative logic selectable
LB1108A
Digital Input
8-channel, Inputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Dry contact or NAMUR inputs
LB7104A
Universal Input/Output (HART)
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Analog input, digital input,
analog output, digital output
LB1001A
Digital Input
2 channels, Dry contact or NAMUR inputs, Installation in Zone 2 or safe area, Galvanic isolation between channels and the bus
LB1015A
Digital Input
15-channel, Active digital signal 24 V DC, Installation in Zone 2 or safe area, Positive or negative logic selectable
LB1101A
Digital Input
2 channels, Inputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Dry contact or NAMUR inputs
LB7004A
Universal Input/Output (HART)
4-channel, Analog input, digital input,
analog output, digital output, Installation in Zone 2 or safe area, Supply circuit 21.5 V (4 mA)
Temperature Input
LB5001A
RTD Converter
1-channel, Converter for 2-, 3- and 4-wire Pt100, slide wire sensors, Installation in Zone 2 or safe area, Simulation mode for service operations (forcing)
LB5002A
Thermocouple Converter
1-channel, Converter for thermocouples and mV-signals, Installation in Zone 2 or safe area, Simulation mode for service operations (forcing)
LB5102A
Thermocouple Converter
1-channel, Input Ex ia, Installation in Zone 2, Div. 2 or safe area, Converter for thermocouples and mV-signals
LB5004A
RTD Converter
4 channels, Converter for 2-, 3- and 4-wire RTDs (Pt100 … Pt1000), slide wire sensors etc., Installation in Zone 2 or safe area, Simulation mode for service operations (forcing)
LB5104A
RTD Converter
4 channels, Inputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Converter for 2-, 3- and 4-wire RTDs (Pt100 … Pt1000), slide wire sensors etc.
LB5105A
Thermocouple Converter
4 channels, Inputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Converter for thermocouples and mV-signals
LB5005A
Thermocouple Converter
4 channels, Converter for thermocouples and mV-signals, Installation in Zone 2 or safe area, Simulation mode for service operations (forcing)
LB5101A
RTD Converter
1-channel, Input Ex ia, Installation in Zone 2, Div. 2 or safe area, Converter for 2-, 3- and 4-wire Pt100, slide wire sensors
Analog Output
LB4002A2
HART Output Isolator
1-channel, Analog output module for 0/4 mA … 20 mA, Installation in Zone 2 or safe area, HART communication via field bus or service bus
LB4102A2
HART Output Isolator
1-channel, Output Ex ia, Installation in Zone 2, Div. 2 or safe area, Analog output module for 0/4 mA … 20 mA
LB4005C2
HART Output Isolator with Shutdown Input
4-channel, Analog output module for 0/4 mA … 20 mA, Installation in Zone 2 or safe area, Module can be exchanged under voltage
LB4102C2
HART Output Isolator with Shutdown Input
1-channel, Output Ex ia, Installation in Zone 2, Div. 2 or safe area, Module can be exchanged under voltage
LB4105C2
HART Output Isolator with Shutdown Input
4-channel, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Module can be exchanged under voltage
LB4106C
HART Output Isolator with Shutdown Input
4-channel, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Module can be exchanged under voltage
LB4105A2
HART Output Isolator
4-channel, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Analog output module for 0/4 mA … 20 mA
LB4106A
HART Output Isolator
4-channel, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Analog output module for 0/4 mA … 20 mA
LB7104A
Universal Input/Output (HART)
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Analog input, digital input,
analog output, digital output
LB4005A2
HART Output Isolator
4-channel, Analog output module for 0/4 mA … 20 mA, Installation in Zone 2 or safe area, HART communication via field bus or service bus
LB4104A2
Output Isolator
4-channel, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Analog output module for 0/4 mA … 20 mA
LB7004A
Universal Input/Output (HART)
4-channel, Analog input, digital input,
analog output, digital output, Installation in Zone 2 or safe area, Supply circuit 21.5 V (4 mA)
LB4101A2
Output Isolator
1-channel, Output Ex ia, Installation in Zone 2, Div. 2 or safe area, Analog output module for 0/4 mA … 20 mA
Digital Output
LB2116E
Digital Output with Shutdown Input
1-channel, 1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area
LB2117E
Digital Output with Shutdown Input
1-channel, 1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area
LB6008A
Digital Output with Shutdown Input
8-channel, Galvanic group isolation, Installation in Zone 2 or safe area, Module can be exchanged under voltage
LB6108A
Digital Output with Shutdown Input
8-channel, Outputs Ex ib, Installation in Zone 2, Div. 2 or safe area, Module can be exchanged under voltage
LB6108C
Digital Output with Shutdown Input
8-channel, Outputs Ex ib, Installation in Zone 2, Div. 2 or safe area, Module can be exchanged under voltage
LB6116E
Digital Output with Shutdown Input
2-channel, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Line fault detection switched on and off
LB6117E
Digital Output with Shutdown Input
2-channel, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Line fault detection switched on and off
LB2016E
Digital Output with Shutdown Input
1-channel, 1 digital output, 2 digital inputs, Installation in Zone 2 or safe area, Inputs and output Ex ic
LB2017E
Digital Output with Shutdown Input
1-channel, 1 digital output, 2 digital inputs, Installation in Zone 2 or safe area, Inputs and output Ex ic
LB6016E
Digital Output with Shutdown Input
2-channel, Outputs Ex ic, Installation in Zone 2 or safe area, Line fault detection switched on and off
LB6017E
Digital Output with Shutdown Input
2-channel, Outputs Ex ic, Installation in Zone 2 or safe area, Line fault detection switched on and off
LB6110A
Digital Output
4-channel, Outputs Ex ia, Installation in Zone 2 or safe area, Line fault detection (LFD)
LB6111A
Digital Output
4-channel, Outputs Ex ia, Installation in Zone 2 or safe area, Line fault detection (LFD)
LB7104A
Universal Input/Output (HART)
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in Zone 2, Div. 2 or safe area, Analog input, digital input,
analog output, digital output
LB2002A
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Output voltage 24 V, max. internal resistance 210 Ω, Installation in Zone 2 or safe area, Positive or negative logic selectable
LB2101A
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Positive or negative logic selectable
LB2101E
Digital Output with Shutdown Input
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Positive or negative logic selectable
LB2102A
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Positive or negative logic selectable
LB2103A
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Positive or negative logic selectable
LB2103E
Digital Output with Shutdown Input
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Module can be exchanged under voltage
LB2104A
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Positive or negative logic selectable
LB2112A
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Positive or negative logic selectable
LB2112E
Digital Output with Shutdown Input
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Module can be exchanged under voltage
LB2113A
Digital Output with Position Feedback
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Positive or negative logic selectable
LB2113E
Digital Output with Shutdown Input
1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in Zone 2, Div. 2 or safe area, Positive or negative logic selectable
LB7004A
Universal Input/Output (HART)
4-channel, Analog input, digital input,
analog output, digital output, Installation in Zone 2 or safe area, Supply circuit 21.5 V (4 mA)
LB6115ES
Digital Output with Shutdown Input
4-channel, Outputs Ex ia, Installation in Zone 2 or safe area, Line fault detection (LFD)
Com Units
LB8106H0628
EasyCom Com Unit for PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Installation in Zone 2, Div. 2 or safe area, Communication via PROFIBUS DP
LB8109H0906
Unicom Com Unit for PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Installation in Zone 2, Div. 2 or safe area, Communication via PROFIBUS DP
LB8105*
Com Unit for PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Installation in Zone 2, Div. 2 or safe area, Communication via PROFIBUS DP
LB8106*
EasyCom Com Unit for PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Installation in Zone 2, Div. 2 or safe area, Communication via PROFIBUS DP
LB8107*
Com Unit for MODBUS RTU
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Installation in Zone 2, Div. 2 or safe area, Communication via MODBUS RTU
LB8108*
Com Unit for PROFIBUS DP/DP-V1 with Time Stamp Option
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Installation in Zone 2, Div. 2 or safe area, Communication via PROFIBUS DP
LB8109*
Unicom Com Unit for PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Installation in Zone 2, Div. 2 or safe area, Communication via PROFIBUS DP
LB8110*
Com Unit for FOUNDATION Fieldbus Modular I/O
Interface between the I/O modules and the PCS/PLC, Com unit for 20 analog or 40 digital channels, Installation in Zone 2, Div. 2 or safe area, Communication via FOUNDATION Fieldbus H1
LB8111A2*
Com Unit for MODBUS TCP
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Installation in Zone 2, Div. 2 or safe area, Communication via MODBUS TCP
Backplanes
LB9022E
Redundancy Base Backplane
Max. 22 slots for I/O modules, Redundancy (field bus and power supply), Installation in Zone 2, Div. 2 or safe area, For MODBUS TCP/IP
LB9022S
Redundancy Base Backplane
Max. 22 slots for I/O modules, 5 SIL 2 output shutdown segments, Installation in Zone 2, Div. 2 or safe area, Redundancy (field bus and power supply)
LB9023E
Base Backplane
Max. 8 slots for I/O modules, For MODBUS TCP/IP, Installation in Zone 2, Div. 2 or safe area, Backplane for LB-System
LB9024S
Extension Backplane
Max. 24 slots for I/O modules, 5 SIL 2 output shutdown segments, Installation in Zone 2, Div. 2 or safe area, Redundancy (power supply)
LB9026A
Base Backplane
Max. 16 slots for I/O modules, For PROFIBUS DP, PROFIBUS DP V1 and MODBUS RTU, Installation in Zone 2, Div. 2 or safe area, Backplane for LB-System
LB9026E
Base Backplane
Max. 16 slots for I/O modules, For MODBUS TCP/IP, Installation in Zone 2, Div. 2 or safe area, Backplane for LB-System
LB9027A
Extension Backplane
Max. 16 slots for I/O modules, Fieldbus type determined by base backplane, Installation in Zone 2, Div. 2 or safe area, Backplane for LB-System
LB9035A
FF Remote I/O Backplane
Max. 5 slots for I/O modules (dual width only), For FOUNDATION Fieldbus H1, Installation in Zone 2, Div. 2 or safe area, Backplane for LB-System
LB9023A
Base Backplane
Max. 8 slots for I/O modules, For PROFIBUS DP, PROFIBUS DP V1 and MODBUS RTU, Installation in Zone 2, Div. 2 or safe area, Backplane for LB-System
LB9025A
Extension Backplane
Max. 8 slots for I/O modules, Fieldbus type determined by base backplane, Installation in Zone 2, Div. 2 or safe area, Backplane for LB-System
LB9029A
Redundancy Base Backplane
Max. 12 slots for I/O modules, Redundancy (field bus and power supply), Installation in Zone 2, Div. 2 or safe area, For PROFIBUS DP, PROFIBUS DP V1 and MODBUS RTU
Enclosures
LB9510-S90-0-0-1-0-F
Field Unit, Stainless Steel
Standard enclosure for LB-System, Max. 5 slots for I/O modules (dual width only), Installation in Zone 2 or safe area, For FOUNDATION Fieldbus H1, Housing: stainless steel 1.4404 / AISI 316L
LB9547-S70-0-0-1-0-0
Redundancy Field Unit, Stainless Steel
Standard enclosure for LB-System, Max. 46 slots for I/O modules, Installation in Zone 2 or safe area, For PROFIBUS DP, PROFIBUS DP V1 and MODBUS RTU, Housing: stainless steel 1.4404 / AISI 316L
LB9547-S70-0-0-1-0-M
Redundancy Field Unit, Stainless Steel
Standard enclosure for LB-System, Max. 46 slots for I/O modules, Installation in Zone 2 or safe area, For MODBUS TCP/IP, Housing: stainless steel 1.4404 / AISI 316L
LB9508-S92-0-0-1-0-0
Field Unit, Stainless Steel
Standard enclosure for LB-System, Max. 8 slots for I/O modules, Installation in Zone 2 or safe area, For PROFIBUS DP, PROFIBUS DP V1 and MODBUS RTU, Housing: stainless steel 1.4404 / AISI 316L
LB9513-PB0-0-0-1-0-0
Redundancy Field Unit, Polyester (GRP)
Standard enclosure for LB-System, Max. 12 slots for I/O modules, Installation in Zone 2 or safe area, For PROFIBUS DP, PROFIBUS DP V1 and MODBUS RTU, Housing: polyester , impact resistant, glass fiber reinforced
LB9516-PB0-0-0-1-0-0
Field Unit, Polyester (GRP)
Standard enclosure for LB-System, Max. 16 slots for I/O modules, Installation in Zone 2 or safe area, For PROFIBUS DP, PROFIBUS DP V1 and MODBUS RTU, Housing: polyester , impact resistant, glass fiber reinforced