Switch Amplifiers

KCD2-SR-Ex1.LB
Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: relay, SIL/IEC 61508

KCD2-SR-Ex2
Switch Amplifier

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: relay, SIL/IEC 61508

KFD2-SOT3-Ex1.LB
Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT3-Ex2
Switch Amplifier

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SR2-Ex1.W
Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: relay, SIL/IEC 61508

KFD2-SR2-Ex1.W.LB
Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: relay, SIL/IEC 61508

KFD2-SR2-Ex2.W
Switch Amplifier

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: relay, SIL/IEC 61508

KFA5-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 103.5 … 126.5 V AC , 45 … 65 Hz, Output: Transistor, SIL/IEC 61508

KFA5-SR2-Ex1.W
Switch Amplifier
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 103.5 … 126 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508

KFA5-SR2-Ex2.W
Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 103.5 … 126 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508

KFA6-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: Transistor, SIL/IEC 61508

KFA6-SR2-Ex1.W
Switch Amplifier
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: relay, SIL/IEC 61508

KFA6-SR2-Ex1.W.LB
Switch Amplifier
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: relay, SIL/IEC 61508

KFA6-SR2-Ex2.W
Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: relay, SIL/IEC 61508

KFD2-SH-Ex1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay output, Fault indication output, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849, Input: NAMUR sensor, Rated voltage: 20 … 35 V DC, Output: relay, SIL/IEC 61508

KFD2-SH-Ex1.T.OP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay output, Fault indication output, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SRA-Ex4
Switch Amplifier
4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: relay

KFD2-ST3-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-ST3-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KHA6-SH-Ex1
Switch Amplifier
1-channel isolated barrier, 115/230 V AC supply, Input for approved dry contacts or SN/S1N sensors, Relay output, Fault indication output, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849, Input: NAMUR sensor, Rated voltage: 85 … 253 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508

KCD2-SON-Ex1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-SON-Ex2.R1
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-SOT-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-SOT-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-SR-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: relay, SIL/IEC 61508

KCD2-SR-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: relay, SIL/IEC 61508

KCD2-ST-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-ST-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFA4-SR2-Ex1.W
Switch Amplifier
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay output with 1 changeover contact, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 90 … 110 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508

KFA4-SR2-Ex1.W.LB
Switch Amplifier
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, Output I: signal output (changeover contact), Output II: optionally signal output/fault signal, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 90 … 110 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508

KFA4-SR2-Ex2.W
Switch Amplifier
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay output with 1 changeover contact per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 90 … 110 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508

KFA5-DU-Ex1.D
Switch Amplifier, Timer Relay
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay and transistor output, Adjustable output timer functions from 10 ms … 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD), Input: NAMUR sensor, Rated voltage: 115 V AC ± 10 %, Output: relay

KFA5-SR2-Ex1.W.LB
Switch Amplifier
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 103.5 … 126 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508

KFA5-SR2-Ex2.W.IR
Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Latching relay output, Line fault detection (LFD), Reversible mode of operation, Input: NAMUR sensor, Rated voltage: 103.5 … 126 V AC , 45 … 65 Hz, Output: relay

KFA6-DU-Ex1.D
Switch Amplifier, Timer Relay
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay and transistor output, Adjustable output timer functions from 10 ms … 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD), Input: NAMUR sensor, Rated voltage: 230 V AC ± 10 %, Output: relay

KFA6-ER-Ex1.W.LB
Conductivity Switch Amplifier
1-channel isolated barrier, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ … 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: relay

KFA6-SR2-Ex2.W.IR
Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Latching relay output, Line fault detection (LFD), Reversible mode of operation, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: relay

KFD2-DU-Ex1.D
Switch Amplifier, Timer Relay
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay and transistor output, Adjustable output timer functions from 10 ms … 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD), Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: relay

KFD2-ELD-Ex16
Ground Fault Detection
16-channel isolated barrier, 24 V DC supply (Power Rail), Analog or digtial field device inputs, Monitors leakage current, Fault relay contact output, LED status indication, Test circuit for validation, Parallel connection for easy integration, Conformal coating, Rated voltage: 20 … 30 V DC

KFD2-ER-Ex1.W.LB
Conductivity Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ … 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 20 … 30 V DC, Output: relay

KFD2-SH-Ex1.T
Switch Amplifier
1-channel isolated barrier, 24 V DC supply, Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay output, Fault indication output, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT3-Ex1.LB.IO
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT3-Ex2.IO
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT3-Ex2.IO-Y1
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SR3-Ex2.2S
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: relay, SIL/IEC 61508

KCD2-SON-Ex1.R1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Usable as signal splitter (1 input and 2 outputs), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-SON-Ex1.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-SON-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-SON-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-SOT-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-SOT-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-ST-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KCD2-ST-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT2-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT2-Ex1.LB.IO
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT2-Ex2.IO
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SR2-Ex2.2S
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: relay, SIL/IEC 61508

KFD2-ST2-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Active fault output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-ST2-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT2-Ex2.IO-Y181008
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor

Frequency Converters

KFD2-UFC-Ex1.D
Frequency Converter with Trip Values

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for NAMUR sensors or dry contacts, Input frequency 1 mHz … 5 kHz, Current output 0/4 mA … 20 mA, Relay and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Frequency current converter + trip value, Rated voltage: 20 … 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508

KFU8-UFC-Ex1.D
Frequency Converter with Trip Values

1-channel isolated barrier, Universal usage at different power supplies, Input for NAMUR sensors or dry contacts, Input frequency 1 mHz … 5 kHz, Current output 0/4 mA … 20 mA, Relay and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Frequency current converter + trip value, Rated voltage: 20 … 90 V DC / 48 … 253 V AC 50 … 60 Hz, Output: 2 x 1 changeover contact + 4-20 mA

KFA6-DWB-Ex1.D
Rotation Speed Monitor
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Input frequency 1 mHz … 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Limit value, Rated voltage: 230 V AC ± 10 %, Output: 2 x 1 changeover contact, SIL/IEC 61508

KFD2-DWB-Ex1.D
Rotation Speed Monitor
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz … 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Limit value, Rated voltage: 20 … 30 V DC, Output: 2 x 1 changeover contact, SIL/IEC 61508

KFD2-UFT-Ex2.D
Frequency Converter with Direction and Synchronization Monitor
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz … 1 kHz, Current output 0/4 mA … 20 mA, Relay and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Function (P2P): Frequency current converter with trip value and rotation direction/slip, Rated voltage: 20 … 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA

KFU8-UFT-Ex2.D
Frequency Converter with Direction and Synchronization Monitor
2-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz … 1 kHz, Current output 0/4 mA … 20 mA, Relay and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Function (P2P): Frequency current converter with trip value and rotation direction/slip, Rated voltage: 20 … 90 V DC / 48 … 253 V AC 50 … 60 Hz, Output: 2 x 1 changeover contact + 4-20 mA

KFA5-DWB-Ex1.D
Rotation Speed Monitor
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Input frequency 1 mHz … 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Limit value, Rated voltage: 115 V AC +/- 10 %, Output: 2 x 1 changeover contact, SIL/IEC 61508

KFD2-SR2-Ex2.W.SM
Standstill and Rotational Direction Monitor
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Function (P2P): Limit value+rotation direction/slip, Rated voltage: 20 … 30 V DC, Output: 2 x 1 changeover contact, SIL/IEC 61508

Solenoid Drivers

KCD0-SD-Ex1.1245
Solenoid Driver

1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Up to SIL3 acc. to IEC 61508, Explosion protection: Ex-Output, SIL/IEC 61508

KFD0-SD2-Ex1.1045
Solenoid Driver

1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL3 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, SIL/IEC 61508

KFD0-SD2-Ex2.1045
Solenoid Driver

2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL3 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-SL2-Ex2.B
Solenoid Driver

2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 20 … 30 V DC, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-SL2-Ex1
Solenoid Driver

1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Lead monitoring, Up to SIL 2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 20 … 30 V DC, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-SL2-Ex1.B
Solenoid Driver

1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 20 … 30 V DC, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-SL2-Ex1.LK
Solenoid Driver

1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.2 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Output, SIL/IEC 61508

KFD0-SD2-Ex1.10100
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL3 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, SIL/IEC 61508

KFD0-SD2-Ex1.1065
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL3 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, SIL/IEC 61508

KFD0-SD2-Ex1.1180
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL3 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, SIL/IEC 61508

KFD0-SD2-Ex2.1245
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Up to SIL3 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-RCI-Ex1
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 20.4 mA at 13.5 V DC, 19 V DC … 30 V DC input, Line fault detection (LFD), Conformal coating, Up to SIL3 acc. to IEC 61508, Input: with prelogic, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-SL2-Ex2
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Lead monitoring, Up to SIL 2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 20 … 30 V DC, Explosion protection: Ex-Output, SIL/IEC 61508

KCD0-SD-Ex1.1245.SP
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Connection via spring terminals, Up to SIL3 acc. to IEC 61508, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-SL2-Ex1.LK-Y1
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Increased input load, Output 45 mA at 11.2 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-SL2-Ex1.LK.1045
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 10 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-SL2-Ex1.LK.1270
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 70 mA at 12.5 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Output, SIL/IEC 61508

KFD2-VM-Ex1.35.L
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 15.3 V DC at 17 mA, 3 logic inputs with AND/OR logic, Service port for isolator function test, Input: with prelogic, Rated voltage: 20 … 30 V DC, Explosion protection: Ex-Output

KCD2-SLD-Ex1.1045
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL3 acc. to IEC 61508

KCD2-SLD-Ex1.1065
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL3 acc. to IEC 61508

KCD2-SLD-Ex1.1245
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL3 acc. to IEC 61508

Relay Modules

KFD0-RO-Ex2
Relay Module

2-channel isolated barrier, 24 V DC supply (loop powered), Relay contact output, Logic input 15 V DC … 30 V DC, non-polarized, Up to SIL3 acc. to IEC 61508, Input: 24 V DC, Output: relay

Transmitter Power Supplies

KCD2-STC-Ex1
SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 … 30 V DC, SIL/IEC 61508

KFD2-CRG2-Ex1.D
Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA … 20 mA, 2 relay contact outputs, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508

KFD2-STC4-Ex1
SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STC4-Ex1-Y1
SMART Transmitter Power Supply, Output Current Sink

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, 0/4 mA … 20 mA current sink output, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STC4-Ex1.2O
SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STC4-Ex2
SMART Transmitter Power Supply

2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA … 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KCD2-STC-Ex1.2O
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 18 … 30 V DC, SIL/IEC 61508

KCD2-STC-Ex1.ES
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 … 30 V DC, SIL/IEC 61508

KFD2-STC3-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, Output 4 mA … 20 mA, SMART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC

KFD2-STC4-Ex1.2O-Y1
SMART Transmitter Power Supply, Output Current Sink
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, current sink, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STC4-Ex1.ES
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 … 30 V DC, SIL/IEC 61508

KFD2-STC4-Ex1.H
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA, Terminals with test points, High field voltage 17.6 V DC, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STC4-Ex2-Y229428
SMART Transmitter Power Supply, Output Current Sink
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, 0/4 mA … 20 mA current sink output, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STV4-Ex1-1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/1 V … 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFU8-CRG2-Ex1.D
Transmitter Power Supply
1-channel isolated barrier, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA … 20 mA, 2 relay contact outputs, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 90 V DC or 48 … 253 V AC, Output: 2 x 1 changeover contact + 4-20 mA

KCD2-STC-Ex1.ES.SP
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 … 30 V DC, SIL/IEC 61508

KCD2-STC-Ex1.HC
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Low power dissipation, Suitable for long field cables (> 1000 m), Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 … 30 V DC, SIL/IEC 61508

KCD2-STC-Ex1.SP
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 … 30 V DC, SIL/IEC 61508

KFD2-HLC-Ex1.D
HART Loop Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7) with transmitter power supply, Usable as signal splitter (1 input and multiple outputs), 3 analog outputs 4 mA … 20 mA, Sink and source mode output, Configurable by keypad

KFD2-HLC-Ex1.D.2W
HART Loop Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7) with transmitter power supply, Usable as signal splitter (1 input and multiple outputs), 2 relay outputs (changeover contacts), 3 analog outputs 4 mA … 20 mA, Sink and source mode output, Configurable by keypad

KFD2-HLC-Ex1.D.4S
HART Loop Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7) with transmitter power supply, Usable as signal splitter (1 input and multiple outputs), 4 relay outputs (NO), 3 analog outputs 4 mA … 20 mA, Sink and source mode output, Configurable by keypad

KFD2-STC4-Ex1.2O.H
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, Terminal blocks with test sockets, High field voltage 17.6 V DC, Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STV3-Ex1-1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, Output 1 V … 5 V, SMART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC

KFD2-STV3-Ex1-2
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, Output 2 V … 10 V, SMART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC

KFD2-STV4-Ex1-2
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/2 V … 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STV4-Ex1.2O-1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STV4-Ex1.2O-2
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/2 V … 10 V, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STV4-Ex2-1
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/1 V … 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KFD2-STV4-Ex2-2
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/2 V … 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508

KCD2-STC-Ex1.2O.DE
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 18 … 30 V DC, SIL/IEC 61508

KCD2-STC-Ex1.2O.ES
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 18 … 30 V DC, SIL/IEC 61508

KCD2-STC-Ex1.HC.SP
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Low power dissipation, Suitable for long field cables (> 1000 m), Connection via spring terminals, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 … 30 V DC, SIL/IEC 61508

KCD2-STC-Ex1.2O.DE
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 18 … 30 V DC, SIL/IEC 61508

KCD2-STC-Ex1.2O
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 18 … 30 V DC, SIL/IEC 61508

Repeaters

KCD2-RR-Ex1
Temperature Repeater

1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Input, Field side connection: Resistance, Control side connection: Resistance, Transfer direction: to the control system

KFD0-CS-Ex1.51P
Current Driver/Repeater

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

KFD0-SCS-Ex1.55
SMART Current Driver/Repeater

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

KFD2-VR4-Ex1.26
Voltage Repeater

1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V … -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V … -20 V, Rated voltage: 19 … 30 V DC, Explosion protection: Ex protection, Field circuit: 0-20 V, Safe area: 0-20 V

KFD0-CS-Ex1.50P
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

KFD0-CS-Ex1.54
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA … 20 mA, Up to SIL3 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Input, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

KFD0-CS-Ex2.51P
Current Driver/Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

KFD2-VR-Ex1.18
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V … 12 V, Voltage output 0 V … 12 V, Rated voltage: 20 … 35 V DC, Explosion protection: Ex-Input, Field circuit: 0-12 V, Safe area: 0-12 V, Transfer direction: to the control system

KFD2-VR2-Ex1.50M
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV … ± 50 mV, Voltage output 0 mV … ± 50 mV, Selectable up/downscale sensor breakage detection, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Input, Field circuit: 0-50 mV, Safe area: 0-50 mV, Transfer direction: to the control system

KCD2-RR-Ex1-Y1
Temperature Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Input, Field circuit: Resistance, Safe area: Resistance, Transfer direction: to the control system

KCD2-RR-Ex1.SP
Temperature Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Input, Field side connection: Resistance, Control side connection: Resistance, Transfer direction: to the control system

KFD0-CS-Ex1.52
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the control system

KFD0-CS-Ex1.53
Current Driver
1-channel isolated barrier, DC supply (loop powered), Current input/output 0 mA … 40 mA, Accuracy 1 %, Low voltage drop, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

KFD0-CS-Ex1.54-Y2
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA … 20 mA, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field

KFD0-CS-Ex2.50P
Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

KFD0-CS-Ex2.52
Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the control system

KFD0-CS-Ex2.54
Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA … 20 mA, Up to SIL3 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Input, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

KFD2-FF-Ex2.RS232
RS 232 Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), RS 232 input/output, Rated voltage: 15 … 35 V DC, Explosion protection: Ex-Input, Field circuit: RS 232, Safe area: RS 232, Transfer direction: to the field

KFD2-VR-Ex1.12
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V … 9 V, Voltage output 0 V … 9 V, Rated voltage: 20 … 35 V DC, Explosion protection: Ex-Input

KFD2-VR-Ex1.19
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V … 10 V, Voltage output -10 V … 10 V, Rated voltage: 20 … 35 V DC, Explosion protection: Ex-Input, Field circuit: 0-10 V, Safe area: 0-10 V, Transfer direction: to the control system

KFD2-VR-Ex1.19-Y109129
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V … 10 V, Transmission frequency up to 50 kHz, Voltage output -10 V … 10 V, Rated voltage: 20 … 35 V DC, Explosion protection: Ex-Input

KFD2-VR2-Ex1.500M
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV … ± 500 mV, Voltage output 0 mV … ± 500 mV, Selectable up/downscale sensor breakage detection, Rated voltage: 19 … 30 V DC, Explosion protection: Ex-Input, Field circuit: 0-500 mV, Safe area: 0-500 mV, Transfer direction: to the control system

KFD0-CS-Ex2.53
Current Driver
2-channel isolated barrier, DC supply (loop powered), Current input/output 0 mA … 40 mA, Accuracy 1 %, Low voltage drop, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

Signal Converters

KCD2-UT2-Ex1
Universal Temperature Converter

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Input: Temperature, Rated voltage: 19 … 30 V DC, Output: 4-20 mA

KFD2-GUT-Ex1.D
Temperature Converter with Trip Values

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA … 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 … 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508

KFD2-UT2-Ex1
Universal Temperature Converter

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 … 30 V DC, Output: 4-20 mA

KFD2-UT2-Ex2
Universal Temperature Converter

2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 … 30 V DC, Output: 4-20 mA

KFD0-CC-Ex1
Current/Voltage Converter
1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 … 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD), Input: Current/voltage, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA

KFD0-TR-Ex1
RTD Converter
1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA … 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection, Input: Resistance, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA

KFD2-PT2-Ex1
Potentiometer Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V … 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 … 35 V DC, Output: 0-10 V, SIL/IEC 61508

KFD2-PT2-Ex1-5
Potentiometer Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA … 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 … 35 V DC, Output: 4-20 mA, SIL/IEC 61508

KFD2-WAC2-Ex1.D
Strain Gauge Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA … ± 20 mA or 0 V … ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 … 35 V DC, Output: 4-20 mA

KFU8-GUT-Ex1.D
Temperature Converter with Trip Values
1-channel isolated barrier, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA … 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 … 90 V DC / 48 … 253 V AC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508

KFD0-TT-Ex1
Thermocouple Converter
1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA … 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Input: Thermocouple, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA

KFD2-PT2-Ex1-1
Potentiometer Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V … 5 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 … 35 V DC, Output: 0-5 V, SIL/IEC 61508

KFD2-PT2-Ex1-4
Potentiometer Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 0 mA … 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 … 35 V DC, Output: 0-20 mA, SIL/IEC 61508

KFD2-PT2-Ex1-6-Y112844
Transformer isolated barrier for potentiometer
1-channel, Input Ex ia IIC, 24 V DC nominal supply voltage, Current output 0 mA … 24 mA, Accuracy 0.05 %, EMC acc. to NAMUR NE 21, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 … 35 V DC, Output: 0-20 mA, SIL/IEC 61508

KFD2-PT2-Ex1-Y98312
Transformer isolated barrier for potentiometer
1-channel, Input Ex ia IIC, 24 V DC supply voltage, Voltage output 0 V … 10 V, Accuracy 0.05 %, EMC acc. to NAMUR NE 21, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 … 35 V DC, Output: 0-10 V, SIL/IEC 61508

KFD2-UT2-Ex1-1
Universal Temperature Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 … 30 V DC, Output: 0-5 V

KFD2-UT2-Ex2-1
Universal Temperature Converter
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 … 30 V DC, Output: 0-5 V

KFD2-WAC2-Ex1.D-Y1
Strain Gauge Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA … ± 20 mA or 0 V … ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Low response time, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 … 35 V DC, Output: 4-20 mA

Trip Amplifiers

KFD2-CRG2-Ex1.D
Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA … 20 mA, 2 relay contact outputs, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508

KFD2-GU-Ex1
Temperature Trip Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, voltage or current input, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware, Sensor breakage detection, Input: Temperature, Rated voltage: 19 … 35 V DC, Output: 2 x 1 changeover contact

KFD2-GUT-Ex1.D
Temperature Converter with Trip Values

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA … 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 … 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508

KFD2-WAC2-Ex1.D
Strain Gauge Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA … ± 20 mA or 0 V … ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 … 35 V DC, Output: 4-20 mA

KFU8-CRG2-Ex1.D
Transmitter Power Supply
1-channel isolated barrier, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA … 20 mA, 2 relay contact outputs, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 … 90 V DC or 48 … 253 V AC, Output: 2 x 1 changeover contact + 4-20 mA

KFU8-GUT-Ex1.D
Temperature Converter with Trip Values
1-channel isolated barrier, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA … 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 … 90 V DC / 48 … 253 V AC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508

KFD2-WAC2-Ex1.D-Y1
Strain Gauge Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA … ± 20 mA or 0 V … ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Low response time, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 … 35 V DC, Output: 4-20 mA

Current Drivers

KCD2-SCD-Ex1
SMART Current Driver

1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508

KFD0-CS-Ex1.51P
Current Driver/Repeater

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

KFD2-SCD-Ex1.LK
SMART Current Driver

1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508

KFD2-SCD2-Ex1.LK
SMART Current Driver

1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508

KFD2-SCD2-Ex2.LK
SMART Current Driver

2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508

KFD0-CS-Ex1.50P
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

KFD0-CS-Ex2.51P
Current Driver/Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

KFD2-CD2-Ex1
Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, I/P and valve positioners, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508

KFD2-CD2-Ex2
Current Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, I/P and valve positioners, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508

KCD2-SCD-Ex1.HC
SMART Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 625 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Suitable for long field cables (> 1000 m), Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508

KCD2-SCD-Ex1.HC.SP
SMART Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 625 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Suitable for long field cables (> 1000 m), Connection via spring terminals, Up to SIL 2 acc. to IEC 61508

KCD2-SCD-Ex1.SP
SMART Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Connection via spring terminals, Up to SIL 2 acc. to IEC 61508

KFD0-CS-Ex1.53
Current Driver
1-channel isolated barrier, DC supply (loop powered), Current input/output 0 mA … 40 mA, Accuracy 1 %, Low voltage drop, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

KFD0-CS-Ex2.50P
Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

KFD2-SCD2-Ex1-Y1
SMART Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508

KFD2-SCD2-Ex2-Y1
SMART Current Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508

KFD0-CS-Ex2.53
Current Driver
2-channel isolated barrier, DC supply (loop powered), Current input/output 0 mA … 40 mA, Accuracy 1 %, Low voltage drop, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

KFD2-CD-Ex1.32-**
Current/Voltage Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current or voltage output, Factory configured input/output, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508

Termination Boards

HISHPSM/32/MM-01
HART Termination Board

32-channel, 24 V DC supply, Interface for serial or parallel wiring options, Dual RS 485 connections, Slot for HART Multiplexer

HiATB01-HART-4X8
HART Communication Board
4 x 8-channel, 24 V DC supply, Suitable for HART communication, Dual RS 485 connections, Used with HiD/HiC Termination Boards, LED for supply status

HiCTB08-SCT-44C-SC-RA
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: screw terminals, black

HiCTB08-SDC-44C-SC-RA
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

HiCTB08-TRI-AOISS-EL-PL
Termination Board
System board for Triconex (approval TAN48), For 8-channel AO card 3805E, For 8 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiCTB08-YRS-RRB-KS-CC-AO08
Termination Board
System board for Yokogawa ProSafe-RS, For 8-channel AO card SAI533, For 8 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB16-SDC-24C-SC-RA
Termination Board
For 16 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

HiCTB16-SDC-44C-SC-RA
Termination Board
For 16 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

HiCTB16-TRI-AIISS-EL-PL
Termination Board
System board for Triconex (approval TAN48), For 32-channel AI cards 3700A, and 3721, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiCTB16-TRI-DIISS-EL-PL
Termination Board
System board for Triconex (approval TAN48), For 32-channel (16+16) DI card 3503E, For 16 modules, Recommended module: HiC2821 (DI), 24 V DC supply, Line fault detection (LFD), Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiCTB16-TRI-DOISS-EL-PL-Y1
Termination Board
System board for Triconex (approval TAN48), For 16-channel DO cards 3604E and 3624, For 16 modules, Recommended modules: HiC2873 (DO), HiC2877 (DO), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiCTB16-YC3-RRB-KS-CC-AI16
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI card AAI143, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB16-YC3-RRB-KS-CC-AO16
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AO card AAI543, For 16 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB16-YRS-RRB-AK-CC-DI16
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel DI card SDV144, For 16 modules, Recommended modules: HiC2831R1 (DI), HiC2853R1 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiCTB16-YRS-RRB-AK-CC-DO16
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel DO card SDV541, For 16 modules, Recommended modules: HiC2871 (DO), HiC2873 (DO), HiC2877 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiCTB16-YRS-RRB-KS-CC-AI16
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel AI card SAI143, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB32-TRI-DIISS-EL-PL
Termination Board
System board for Triconex (approval TAN48), For 64-channel (32+32) DI card 3564, For 32 modules, Recommended module: HiC2821 (DI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiCTB32-TRI-DOISS-EL-PL-Y1
Termination Board
System board for Triconex (approval TAN48), For 32-channel (16+16) DO cards 3625 and 3664, For 32 modules, Recommended modules: HiC2873 (DO), HiC2877 (DO), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiCTB32-YC3-RRB-AK-CC-DX32
Termination Board
System board for Yokogawa CENTUM VP, For 32-channel DI card ADV151, For 32 modules, Recommended module: HiC2821 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiCTB32-YC3-RRB-AK-CC-DX32-Y1
Termination Board
System board for Yokogawa CENTUM VP, For 32-channel DO card ADV551, For 32 modules, Recommended module: HiC2871 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiDTB08-SDC-89C-SC-RA
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

SC-GPCS-UNI16-PF
Termination Board
System board for Honeywell Experion PKS, Series C, For 16-/32-channel cards CC-TDIL01/11, CC-TDOB01/11, CC-TAIX01/11 and CC-TAOX01/11, For 16 modules, Recommended modules: HiC2821 (DI), HiC2871 (DO), HiC2025 (AI), HiC2031 (AO), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

SC-GPDS-AIO16-PF
Termination Board
System board for Honeywell Experion PKS, Series C, For 16-channel cards CC-TAIX01/11 (AI) and CC-TAOX01/11 (AO), For 16 modules, Recommended modules: HiD2029SK (AI), HiD2081 (Temp.), HiD2031 (AO), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

TB-C3-AI8-KS
Termination Board
System board for Yokogawa CENTUM CS3000 R3, For 8-channel AI card AAI135, 24 V DC supply (loop powered), Field side: spring terminals, green, Control side: Yokogawa system connector, 40-pin, HART communication: 26-pin flat cable

TB-C3-AIO8-KS
Termination Board
System board for Yokogawa CENTUM CS3000 R3, For 8-channel AI/AO card AAI835, 24 V DC supply (loop powered), Field side: spring terminals, green, Control side: Yokogawa system connector, 40-pin, HART communication: 26-pin flat cable

TB-C3-DI32-AKB-Y188683
Termination Board
System board for Yokogawa CENTUM CS3000 R3, For 32-channel DI card ADV151, For 64-channel DI card ADV161 (2 boards required), 24 V DC supply, Field side: spring terminals, green, Control side: Yokogawa system connector, 50-pin

TB-C3-DO32-AKB-Y188682
Termination Board
System board for Yokogawa CENTUM CS3000 R3, For 32-channel DO card ADV551, For 64-channel DO card ADV561 (2 boards required), 24 V DC supply, Field side: screw terminals, green, Control side: Yokogawa system connector, 50-pin

TB-RS-AI16-KS-186102
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel AI card SAI143, Field side: spring terminals, green, Control side: Yokogawa system connector, 40-pin, HART communication: 26-pin flat cable

TB-RS-DI16-AKB-185847
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel DI card SDV144, 24 V DC supply, Field side: spring terminals, green, Control side: Yokogawa system connector, 50-pin

TB-RS-DO16-AKB-204061
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel DO card SDV541, 24 V DC supply, Field side: spring terminals, green, Control side: Yokogawa system connector, 50-pin

TB-RS-DO8-AKB
Termination Board
System board for Yokogawa ProSafe-RS, For 8-channel DO card SDV531, 24 V DC supply (loop powered), Field side: spring terminals, green, Control side: Yokogawa system connector, 50-pin

FC-GPCD-SDI16-PF
Termination Board
System board for Honeywell Safety Manager, For 16-channel DI card SDI-1624, For 8 modules, Recommended module: HiC2822 (DI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin

FC-GPCS-RIO16-PF
Termination Board
System board for Honeywell Universal Safety IO, System board for Honeywell Universal Process IO, For 16-channel cards USIO and UPIO, For 16 modules, Recommended modules: HiC2831R2 (DI), HiC2853R2 (DI), HiC2871 (DO), HiC2025 (AI), HiC2031 (AO), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

FC-GPCS-SAI16-PF
Termination Board
System board for Honeywell Safety Manager, For 16-channel AI card SAI-1620m, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin

FC-GPCS-SAO08-PF
Termination Board
System board for Honeywell Safety Manager, For 4 pieces 2-channel card SAO-0220m, For 8 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin

FC-GPCS-SDI16-PF
Termination Board
System board for Honeywell Safety Manager, For 16-channel DI cards SDIL-1608 and SDI-1624, For 16 modules, Recommended modules: HiC2821 (SIL 2), HiC2851 (SIL 3), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin

FC-GPCS-SDO08-PF
Termination Board
System board for Honeywell Safety Manager, For 8-channel card SDO-0824, For 8 modules, Recommended module: HiC2871 (DO), Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin

FC-GPDD-SAI16-PF
Termination Board
System board for Honeywell Safety Manager, For 16-channel AI card SAI-1620m, For 8 modules, Recommended module: HiD2030 (AI), HiD2082 (Temp.), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin

HiATB01-HART-2X16
HART Communication Board
2 x 16-channel, 24 V DC supply, Suitable for HART communication, Dual RS 485 connections, Used with HiD/HiC Termination Boards, LED indicator for supply status

HiATB01-HART-4X8-Y1
HART Communication Board
4 x 8-channel, 24 V DC supply, Suitable for HART communication, Dual RS 485 connections, Used with HiD/HiC Termination Boards, LED for supply status

HiCTB08-SPT-44C-SP-RS-Y1
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: spring terminals, blue, Safe area: spring terminals, black

HiCTB08-YC3-RRB-KS-CC-AM08
Termination Board
System board for Yokogawa CENTUM VP, For 8-channel AI card AAI135, For 8-channel AI/AO card AAI835, For 8 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB08-YRS-RRB-AK-CC-DI16
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel DI card SDV144, For 8 modules, Recommended module: HiC2832R1 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiCTB08-YRS-RRB-AK-CC-DO08
Termination Board
System board for Yokogawa ProSafe-RS, For 8-channel DO card SDV531, For 8 modules, Recommended module: HiC2871 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiCTB16-SCT-44C-SC-RA
Termination Board
For 16 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: screw terminals, black

HiCTB16-TRI-DIISD-EL-PL
Termination Board
System board for Triconex (approval TAN48), For 64-channel (32+32) DI card 3564, For 16 modules, Recommended module: HiC2822 (DI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiCTB16-YC3-RRB-AK-CC-DX32
Termination Board
System board for Yokogawa CENTUM VP, For 32-channel DI card ADV151, For 16 modules, Recommended module: HiC2822 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiCTB16-YC3-RRB-KS-CC-AI16-Y1
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI card AAI141, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB16-YC3-RRB-KS-CC-AM16
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAI841, For 16 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB16-YC3-RRB-KS-CC-AM16-Y1
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAB841, For 16 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB16-YRS-RRB-KS-CC-AI16-Y1
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel AI card SAV144, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB32-SDC-24C-SC-RA
Termination Board
For 32 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

HiCTB32-TRI-AIISS-EL-PL
Termination Board
System board for Triconex (approval TAN48), For 64-channel (32+32) AI cards 3704E and 3720, For 32 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB08-SCT-44C-SC-RA
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: screw terminals, black

HiDTB08-SCT-49C-SC-RA
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: screw terminals, black

HiDTB08-SCT-99C-SC-RA
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: screw terminals, black

HiDTB08-SDC-44C-SC-RA
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

HiDTB08-SPT-99C-SP-RS-Y1
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: spring terminals, blue, Safe area: spring terminals, black

HiDTB08-TRI-AIISD-EL-PL
Termination Board
System board for Triconex, For 32-channel AI cards 3700A, and 3721, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB08-TRI-AIISD-EL-SC
Termination Board
System board for Triconex, For 32-channel AI cards 3700A, and 3721, For 8 modules, Recommended module: HiD2082 (TI), 24 V DC supply, Hazardous area: screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB08-TRI-AOISD-EL-PL
Termination Board
System board for Triconex, For 8-channel AO card 3805E, For 8 modules, Recommended module: HiD2031 (AO), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB08-TRI-DOISD-EL-PL-Y1
Termination Board
System board for Triconex, For 16-channel DO cards 3604E and 3624, For 8 modules, Recommended modules: HiD2872 (DO), HiD2876 (DO), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB08-YC3-RRB-AK-CC-DX32
Termination Board
System board for Yokogawa CENTUM VP, For 32-channel DI card ADV151, For 8 modules, Recommended module: HiD2824 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiDTB08-YC3-RRB-KS-CC-AI16
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI card AAI143, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), HiD2082 (TI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiDTB08-YC3-RRB-KS-CC-AO16
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AO card AAI543, For 8 modules, Recommended module: HiD2038Y (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiDTB08-YRS-RRB-AK-CC-DO16
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel DO card SDV541, For 8 modules, Recommended modules: HiD2872 (DO), HiD2876 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiDTB08-YRS-RRB-KS-CC-AI16
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel AI card SAI143, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiDTB16-SCT-44C-SC-RA
Termination Board
For 16 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: screw terminals, black

HiDTB16-SDC-44C-SC-RA
Termination Board
For 16 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

HiDTB16-TRI-AIISD-EL-PL
Termination Board
System board for Triconex, For 32-channel AI cards 3700A, and 3721, For 16 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB16-TRI-AIISS-EL-PL
Termination Board
System board for Triconex, For 32-channel AI cards 3700A, and 3721, For 16 modules, Recommended modules: HiD2025 (AI), HiD2029 (AI), HiD2081 (TI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB16-TRI-DIISD-EL-PL
Termination Board
System board for Triconex, For 32-channel (16+16) DI card 3503E, For 16 modules, Recommended modules: HiD2822 (DI), HiD2842 (DI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB16-TRI-DIISQ-EL-SC
Termination Board
System board for Triconex, For 64-channel (32+32) DI card 3564, For 16 modules, Recommended module: HiD2844 (DI), 24 V DC supply, Hazardous area: screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB16-TRI-DOISD-EL-PL-Y2
Termination Board
System board for Triconex, For 32-channel (16+16) DO cards 3625 and 3664, For 16 modules, Recommended modules: HiD2872 (DO), HiD2876 (DO), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB16-YC3-RRB-AK-CC-DX32
Termination Board
System board for Yokogawa CENTUM VP, For 32-channel DO card ADV551, For 16 modules, Recommended modules: HiD2872 (DO), HiD2876 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin

HiDTB16-YC3-RRB-KS-CC-AI16
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI card AAI143, For 16 modules, Recommended module: HiD2081 (TI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiSHPMM/64/CONA-01
HART Termination Board
64-channel, 24 V DC supply, Connection of two Multiplexers to HART enabled Honeywell TDC 3000 FTA’s , Redundant power supply connections, Dual RS 485 connections, HART loop connection via four 20-pin flat ribbon connectors, Compact design

HiSHPSM/32/TB-02
Termination Board
Ideal for retrofitting existing installations, Interface for serial or parallel wiring options, 37-pin Sub-D connectors, Redundant power supply connections, HART filter options, Fuse options

HiSHPSM/32/TB-02/HF32
HART Termination Board
32-channel, 24 V DC supply, For analog output cards, HART output filters, Interface for serial or parallel wiring options, 37-pin Sub-D connectors, Slot for HART Multiplexer

HiSHPTB/32/FOX2001C-02
HART Termination Board
IA 200 replacement FTA, Designed for FBMs 201, 204, 215 and 237, 25-pin Sub-D connectors, PCS wiring, Redundant power supply connections, Easy to add line impedance

HiSHPTB/32/TR-AI-01
HART Termination Board
Triconex 3700A and 3721 replacement FTA, 2- or 3-wire or self powered transmitters, Outputs: 2 x 16 channels, 0 V … 10 V differential, DC coupled (makes 32 channels), Short-circuit protected, Plug-n-play wiring capabilities

HiSHPTB/32/TR-AI-03
HART Termination Board
Triconex 3704E and 3720 replacement FTA, 2- or 3-wire or self powered transmitters, Outputs: 1 x 32 channels, 0 V … 5 V differential, DC coupled, Short-circuit protected, Plug-n-play wiring capabilities

HiSHPTB/32/TR-AO-01
HART Termination Board
Triconex 3805E replacement FTA, 32 channels of I/O, Outputs: 4 x 8 channels, 4 mA … 20 mA current loop, DC coupled, Short-circuit protected, HART analog output filters

SC-GPCD-DI32-PF
Termination Board
System board for Honeywell Experion PKS, Series C, For 32-channel card CC-TDIL01/11, For 16 modules, Recommended module: HiC2822 (DI), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

SC-GPDD-AIO16-PF
Termination Board
System board for Honeywell Experion PKS, Series C, For 16-channel cards CC-TAIX01/11 (AI) and CC-TAOX01/11 (AO), For 8 modules, Recommended modules: HiD2030SK (AI), HiD2081 (Temp.), HiD2032 (AO), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

SC-GPDD-DO32-PF
Termination Board
System board for Honeywell Experion PKS, Series C, For 32-channel card CC-TDOB01/11, For 16 modules, Recommended module: HiD2874 (DO), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

TB-C3-AI16-KS-132049 (9295)
Termination Board
System board for Yokogawa CENTUM CS3000 R3, For 16-channel AI cards AAI141, AAI143, 24 V DC supply, Field side: screw terminals, green, Control side: Yokogawa system connector, 40-pin, HART communication: 26-pin flat cable

TB-C3-AIO16-KS-243011
Termination Board
System board for Yokogawa CENTUM CS3000 R3, For 16-channel AI cards AAV141, AAV143, For 16-channel AI cards AAI141, AAI143, For 16-channel AI/AO cards AAI841, AAB841, For 16-channel AO card AAI543, Field side: spring terminals, green, Control side: Yokogawa system connector, 40-pin

TB-RS-AI16V-KS
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel AI card SAV144, 24 V DC supply (loop powered), Field side: spring terminals, green, Control side: Yokogawa system connector, 40-pin, HART communication: 26-pin flat cable

FC-GPDS-SAI16-PF
Termination Board
System board for Honeywell Safety Manager, For 16-channel AI card SAI-1620m, For 16 modules, Recommended modules: HiD2029SK (AI), HiD2081 (Temp.), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin

FC-GPDS-SFG16-PF
Termination Board
System board for Honeywell Safety Manager, For 16-channel DO card DO-1624, For 16-channel AI card SAI-1620m, For 16 modules, Recommended module: HiD2035 (AO), For gas and fire detectors, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin

HiCTB16-HIM-RAC-SP-AO1601
Termination Board
System board for HIMA, HIMax, For 16-channel card X-AO 1601 (AO, single mode), 16-channel card X-AO 1601 (AO, redundant mode on request), For 16 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiCTB16-HIM-RAC-SP-DI3202
Termination Board
System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 16 modules, Recommended module: HiC2832 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiCTB16-HIM-RAC-SP-DI320X
Termination Board
System board for HIMA, HIMax, For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI), For 16 modules, Recommended modules: HiC2822 (DI), HiC2842 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiCTB16-YC3-RRB-KS-CC-AI16-Y2
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI card AAV141, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiCTB32-HIM-RAC-SP-AI320X
Termination Board
System board for HIMA, HIMax, For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI), For 32 modules, Recommended modules: HiC2025 (AI), HiC2081 (TI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiCTB32-HIM-RAC-SP-DI3202
Termination Board
System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 32 modules, Recommended modules: HiC2831 (DI), HiC2853 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiCTB32-HIM-RAC-SP-DI320X
Termination Board
System board for HIMA, HIMax, For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI), For 32 modules, Recommended modules: HiC2821 (DI), HiC2841 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiCTB32-HIM-RAC-SP-DO3201
Termination Board
System board for HIMA, HIMax, For 32-channel card X-DO 32 01 (DO), For 32 modules, Recommended module: HiC2873 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiCTB32-HIM-RAS-SP-AI320X
Termination Board
System board for HIMA, HIMax, For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI), For 32 modules, Recommended module: HiC2027 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin, Safe area: spring terminals, black
HiCTB32-HIM-RAS-SP-DI3202
Termination Board
System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 32 modules, Recommended modules: HiC2831 (DI), HiC2853 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin, Safe area: spring terminals, black

HiCTB32-HIM-RAS-SP-DI320X
Termination Board
System board for HIMA, HIMax, For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI), For 32 modules, Recommended modules: HiC2821 (DI), HiC2841 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin, Safe area: spring terminals, black

HiDTB04-DVM-IDC1-SC-R1-DI16
Termination Board
System board for Emerson DeltaV, For one 32-channel DI card via 40-pin Mass Termination Block, For 4 modules/16 channels, Recommended module: HiD2844 (DI), Volt-free fault indication output, 24 V DC supply, reverse polaritiy protected, optional daisychainable, Hazardous area: screw terminals, blue, Safe area: IDC connector, 20-pin

HiDTB04-DVM-IDC1-SC-R2-DI16
Termination Board
System board for Emerson DeltaV, For one 32-channel DI card via 40-pin Mass Termination Block, For 4 modules/16 channels, Recommended module: HiD2844 (DI), Volt-free fault indication output, 24 V DC supply, reverse polaritiy protected, optional daisychainable, Hazardous area: screw terminals, blue, Safe area: IDC connector, 20-pin

HiDTB04-DVM-IDC3-SC-R2-DO08
Termination Board
System board for Emerson DeltaV, For one 8-channel DO card via 16-pin Mass Termination Block, For one 32-channel DO card via 40-pin Mass Termination Block, For 4 modules/8 channels, Recommended module: HiD2872 (DO), Volt-free fault indication output, 24 V DC supply, reverse polaritiy protected, optional daisychainable, Hazardous area: screw terminals, blue, Safe area: IDC connector, 16 pin and 20-pin

HiDTB04-DVM-IDC4-SC-NO-AM16
Termination Board
System board for Emerson DeltaV, For two 8-channel AI/AO cards via 16-pin Mass Termination Block, For one 16-channel AI/AO card via 48-pin Mass Termination Block, For 4 modules/16 channels, Recommended module: HiD2024 (AI/AO), Line fault transparency (LFT), HART compatible, 24 V DC supply, reverse polaritiy protected, optional daisychainable, Hazardous area: screw terminals, blue, Safe area: IDC connector, 16 pin and 24-pin

HiDTB08-DVM-IDC4-SC-R1-SM32
Termination Board
System board for Emerson DeltaV, For two 8-channel AI/AO/DO cards via 16-pin Mass Termination Block, For four 8-channel DI cards via 16-pin Mass Termination Block, For 8 modules/16 or 32 channels, Recommended modules: HiD2030SK (AI), HiD2038 (AO), HiD2824 (DI), HiD2844 (DI), HiD2872 (DO), Volt-free fault indication output, 24 V DC supply, Hazardous area: screw terminals, blue, Safe area: IDC connector, 16-pin

HiDTB08-SDC-49C-SC-RA
Termination Board
For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Safe area: Sub-D connector (male), 37-pin

HiDTB08-TRI-DIISQ-EL-SC
Termination Board
System board for Triconex, For 64-channel (32+32) DI card 3564, For 8 modules, Recommended module: HiD2844 (DI), 24 V DC supply, Hazardous area: screw terminals, blue, Safe area: ELCO socket, 56-pin

HiDTB08-YC3-RRB-KS-CC-AI16-Y1
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI card AAV141, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiDTB08-YC3-RRB-KS-CC-AM16
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAB841, For 8 modules, Recommended modules: HiD2026 (AI), HiD2038Y (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiDTB08-YC3-RRB-KS-CC-AM16-Y1
Termination Board
System board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAI841, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), HiD2032 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiDTB08-YRS-RRB-KS-CC-AI16-Y1
Termination Board
System board for Yokogawa ProSafe-RS, For 16-channel AI card SAV144, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin

HiDTB16-HIM-RAC-SP-AI320X
Termination Board
System board for HIMA, HIMax, For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI), For 16 modules, Recommended module: HiD2030 (AI), HiD2082 (Temp.), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiDTB16-HIM-RAC-SP-DO3201
Termination Board
System board for HIMA, HIMax, For 32-channel card X-DO 32 01 (DO), For 16 modules, Recommended module: HiD2872 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiS1132/CON8-H-LTX-02
HART Termination Board
APACS/QUADLOG replacement FTA, Bailey Infi 90 replacement FTA, Product connector; PCS wiring, Easy switch selectable configurations for AO and AI

HiSHPTB/32/HONB-AI-01
HART Termination Board
TDC 3000 replacement FTA, Short-circuit protected, Process control system wirings, Redundant power supply connections, Field terminal blocks that are Honeywell FTA compatible, Honeywell “B” size footprint

HiSHPTB/32/HONB-AI-R-01
HART Termination Board
TDC 3000 replacement FTA, Short-circuit protected, Redundant PCS wirings, Redundant power supply connections, Field terminal blocks that are Honeywell FTA compatible, Honeywell “B” size footprint

HiSHPTB/32/HONB-AO-R-01
HART Termination Board
TDC 3000 replacement FTA, Short-circuit protected, HART analog output filters, Redundant PCS wirings, Redundant power supply connections, Field terminal blocks that are Honeywell FTA compatible, Honeywell “B” size footprint

TB-C3-AIO16-KS1-182610 (9295)
Termination Board
System board for Yokogawa CENTUM CS3000 R3, For 16-channel AI/AO card AAI841, 24 V DC supply, Field side: screw terminals, green, Control side: Yokogawa system connector, 40-pin, HART communication: 26-pin flat cable

TB-UNI-AKB
Termination Board
System board for Yokogawa CENTUM CS3000 R3, 24 V DC supply (loop powered), Field side: spring terminals, green, Control side: Yokogawa system connector, 50-pin

HiSHPTB/32/TR-AI-02
HART Termination Board
Triconex 3701 replacement FTA, 2- or 3-wire or self powered transmitters, Outputs: 2 x 16 channels, 0 V … 10 V differential, DC coupled (makes 32 channels), Short-circuit protected, Plug-n-play wiring capabilities

HiSHPTB/32/TR-DO-01
HART Termination Board
Triconex 3604E replacement FTA, Outputs: 2 x 16 channels, 24 V DC, opto-isolated, non commoned, Short-circuit protected, Plug-n-play wiring capabilities

HiSHPTB/32/YOK-AI-R-02
HART Termination Board
Yokogawa Centum 3000 CS AAI135 replacement FTA, 32 channels of I/O, 2- or 3-wire or self powered transmitters, Short-circuit protected, Plug-n-play wiring capabilities

HiSHPTB/32/YOK-AIO-R-02
HART Termination Board
Yokogawa Centum 3000 CS AAI835 replacement FTA, 32 channels of I/O, 16 channels AI and 16 channels AO, 2- or 3-wire or self powered transmitters or valves, Short-circuit protected, Plug-n-play wiring capabilities

HiDTB16-HIM-NLC-SP-AI3201
Termination Board
System board for HIMA, HIMax, For 32-channel card X-AI 3201 (AI), For 16 modules, Recommended module: HiD2036 (AO), For gas and fire detectors, Hazardous area: spring terminals, blue, Safe area: HIMA system connector, 96-pin

HiSHPTB/32/TR-AI-01-Y1
HART Termination Board
Triconex 3700A and 3721 replacement FTA, 2- or 3-wire or self powered transmitters, Outputs: 2 x 16 channels, 0 V … 10 V differential, DC coupled (makes 32 channels), Short-circuit protected, Plug-n-play wiring capabilities, Optimized for use in floating power configurations